Software Applications by Meca Enterprises, Inc. | ||||||||
| Stackdes (Self Supported Module), $725.00 | ||||||||
STACKDES (Self Supported) is a stand-alone executable program that performs the overall structural analysis of Self Supported Steel Stacks. It uses a stiffness matrix to completely model the stack and it's loadings, and then applies the appropriate acceptance criteria based upon the user selected design code. The program also calculates the natural frequency of the structure so that the dynamic along wind and dynamic across wind (vortex) loads can be applied to the stack. The software includes many industry recognized codes and standards. Stackdes includes an integrated version of Cone, Baseplate, and Strucflg. That means the user can automatically design these components directly within Stackdes. A security key is shipped with each order, by default a USB security key will be shipped. We also offer a Parallel security key. If you prefer a Parallel security key please specify in the Comment Section of the order page. The security key will allow the user to operate the software. The installation of the software can be installed on multiple computers, but will be limited by the number of licenses purchased. At the end of the lease period (one year), the software will revert to the demo mode. | ||||||||
| Cone, $100.00 | ||||||||
| (English & Metric Units) Performs design and analysis of concentric conical shell transitions subjected to axial loading and bending moment. The program has a complete library of AISC shapes, which can be selected from to design the stiffening rings for either cylinder to cone junction. All calculations are based upon "API RP 2A-WSD, 1993." | ||||||||
| Wind98, $100.00 | ||||||||
| (English Units Only) Calculates wind pressures per ASCE 7-98 for All types of buildings and structures. Performs all flexible structure calculations for the gust factor based upon the natural frequency of the structure. Also calculates the topographic factors and provides a comprehensive list of all shape factors for the structure and attachments. | ||||||||
| BasePlate, $100.00 | ||||||||
| (English Units Only) This program simplifies the design and analysis of a base plates vessels or stack. The program can accommodate a single base plate or an anchor bolt chair. For base plates it can handle no gussets, one gusset per bolt, or two gussets per bolt. The program handles anchor chairs with segmented top plates, or continuous top plates with one or two gussets per bolt. Design of the plates, gussets, and local stress for the shell is performed. | ||||||||
| Strucflg, $100.00 | ||||||||
| (Metric & English Units) Have you ever had to design a plate flange for structural loads? Some examples of applications include derrick leg flanges, monopole flanges, and stack body flanges. These types of flanges are often difficult to design because there is not a commonly accepted procedure for the design of these types of flanges. STRUCFLG handles structural flanges either with or without gusset plates. The program also considers the preload that should be placed on the bolt in order to keep the joint in compression. Designing plate flanges has finally become very easy. | ||||||||
| Saddle, $100.00 | ||||||||
| (Metric & English Units) Perform analysis of a horizontal vessel supported on two saddles. The program performs a complete analysis of the vessels based upon L. P. Zick's analysis procedure. The program allows the user to specify the wind load, thermal loads, liquid load, and seismic loads on the vessel. A complete analysis is also performed on the saddle, calculating stresses on bolts, base plate, web, stiffeners, and wear plate. | ||||||||
| Wind Package, $200.00 | ||||||||
| Wind Package - includes Wind98, Wind02, Wind05 | ||||||||
| Wind02, $100.00 | ||||||||
Calculates wind pressures per ASCE 7-02 "Minimum Design Loads for Buildings and Other Structures" for All types of buildings and structures. Performs Gust calculations for Rigid and flexible structures, with the gust factor for flexible structures based upon the natural frequency and damping of the structure. Also calculates the topographic factors and provides a comprehensive list of all shape factors for the structure and attachments. Wind02 will handle low rise (<= 60 ft) buildings, using either the detailed (Method 2) or the simplified (Method 1) provisions. Wind02 can also be used to calculate wind loads on buildings greater than 60 ft in height. Wind02 will handle the following types of roof's: Different wind directions can be changed easily by re-entering the width and depth of the structure relative to the wind. All force coefficients are calculated for windward walls, leeward walls, side walls, roof's perpendicular to ridge, roof's parallel to ridge, and roof overhangs. Wind02 also calculates the force coefficients and wind pressures for Components and Cladding, simply by entering the width, span, and zone for the component. | ||||||||
| GlassPro, $199.00 | ||||||||
| GlassPro performs loading resistance analysis for glass, using the criteria contained in the ASTM E1300 standard. The program handles multiple glass construction, including Monolithic, Laminated, or Insulated Glass. Using ASTM E1300 can be quite tedious and time consuming to use, because of the many charts and graphs which must be used to perform the analysis. GlassPro makes this analysis very simple, since all of these curves have been curvefit and incorporated directly into the software. The software supports ASTM E1300-04 and ASTM E1300-02/03. | ||||||||
| Wind05, $100.00 | ||||||||
Calculates wind pressures per ASCE 7-05 Minimum Design Loads for Buildings and Other Structures for all types of buildings and structures. Performs Gust calculations for Rigid and flexible structures, with the gust factor for flexible structures based upon the natural frequency and damping of the structure. Also calculates the topographic factors and provides a comprehensive list of all shape factors for the structure and attachments. Wind05 will handle low rise (<= 60 ft) buildings, using either the detailed (Method 2) or the simplified (Method 1) provisions. Wind05 can also be used to calculate wind loads on buildings greater than 60 ft in height. Wind05 will handle the following types of roof's: Different wind directions can be changed easily by re-entering the width and depth of the structure relative to the wind. All force coefficients are calculated for windward walls, leeward walls, side walls, roof's perpendicular to ridge, roof's parallel to ridge, and roof overhangs. Wind05 also calculates the force coefficients, and wind pressures for Components and Cladding, simply by entering the width, span, and zone for the component. Wind05 now calculates windward and leeward pressure for Parapets on Monoslope, Gabled, and Hipped type roofs. There have been significant changes since the last revision of ASCE 7-02. Some of these changes include: New parameters for Monoslope roofs, Pitched and Troughed roofs have been added to Open Buildings, Parapets coefficients have changed, Solid Signs and Freestanding walls have changed, and formulas for Monoslope, Pitched, Troughed, and Solid Signs have changed and or been added to ASCE 7-05. | ||||||||
| Strake, $175.00 | ||||||||
| Strake is a stand-alone program used to design the layout of Helical Strakes. The software also provides a reference picture for forming and bending the strakes. | ||||||||
| Stack Design (Self Supported and Guy Wire Supported), $1,250.00 | ||||||||
STACKDES is a stand-alone executable program that performs the overall structural analysis of Self Supported or Guy Wire Supported Steel Stacks. It uses a stiffness matrix to completely model the stack and it's loadings, and then applies the appropriate acceptance criteria based upon the user selected design code. The program also calculates the natural frequency of the structure so that the dynamic along wind and dynamic across wind (vortex) loads can be applied to the stack. Stackdes includes an integrated version of Cone, Baseplate, and Strucflg. That means the user can automatically design these components directly within Stackdes. A security key is shipped with each order, by default a USB security key will be shipped. We also offer a Parallel security key. If you prefer a Parallel security key please specify in the Comment Section of the order page. The security key will allow the user to operate the software. The installation of the software can be installed on multiple computers, but will be limited by the number of licenses purchased. At the end of the one year lease period, the software will revert to the demo mode. |
| Home | FAQ | Sell your software |
| About us | Contact Us | Safe Shopping | Privacy |
| Copyright © 2006. KRC Technologies All Rights Reserved. |